Specifications

Type Compact type
Display specification Analog
Measurement target Soft rubber, sponge, felt, hard foam, winder
Category in standards Type E
Applicable standard JIS K 6253
Needle shape Shaft diameter
Tip shape Semi-sphere
Tip angle
Tip diameter ø5mm
Tip curvature
Pressure surface shape 44×18mm
Protrusion of needle from pressure surface 2.5mm
Minimum graduation 1 ̊
Loading device WE, WA, WD, spring force (mN) HE, HA, HD hardness Coil spring method
WE=550+75HE
(10 scale 1300mN, 90 scale 7300mN)
Accuracy of spring force ±68.6mN
Functions Peak hold
External dimensions Approx. 56(W)×33.5(D)×144(H)mm
Mass 300g
Power supply

FEATURES

Digital / Dial Durometers are suitable for testing the nature of the following materials -natural rubber, neoprene, polyesters, P.V.C., leather, nitrite rubber, wax, vinyl, cellulose acetates, glass polystyrene, etc.

         Technical Data

  • Designed in accordance with the ASTM D 2240, ISO868, ISO 7619, DIN 53 505, JIS K 6253, and JIS K 7215 specifications.
  • Units are available in both Shore A and Shore D scales, and will test a wide variety of applications.
  • The Digital Durometer is provided with data hold function, permitting the operator to make an error-free reading on the LCD screen.
  • The Dial Durometer is provided with a peak retaining hand for error-free reading.

    Testing stand applications
    These stands are used to mount Durometers. They allow constant-pressure hardness measurement by pressing the Durometer vertically on a work piece.

  • Anyone can perform repeatable hardness measurement due to fewer possibilities of human error and measurement variations.
  • The supplied weights can be attached directly to a Durometer and allow constant-pressure hardness measurement of large samples for which a stand cannot be used.
  • The supplied weights are used for calibrating the spring tension of Durometers.

Peak hold function

The peak hold indicator attached to the analog display is very useful for peak value measurement.