Image Analysis Software
OLYMPUS Stream

Contact
OLYMPUS Stream
Olympus
Contact

Available on backorder

Easy-to-Use Interface and Step-by-Step Guidance

Smart Technologies for Crisp Image Capture

  • Tools for live images 
  • Panorama and extended depth focus 
  • Saving and recalling acquisition settings 

High Efficiency on Repeating Tasks

  • Guided operation 
  • Quantitative analysis
  • Automatic tools for efficient image acquisition
  • Efficient report creation

Designed for Olympus Hardware

Seamlessly Integration with Olympus Optical Microscopes

  • Upright microscopes
  • Inverted microscopes
  • Semiconductor microscopes
  • Stereo microscopes
  • LEXT 3D measuring laser microscope
  • DSX digital microscope

Working with Olympus Digital Cameras

  • Color fidelity
  • High resolution
  • Real-time on-screen imaging

Dedicated Observation Methods

  • HDR imaging for image contrast improvement
  • Unique ‘MIX’ observation mode providing sample details from both brightfield and darkfield

Solving Your Inspection Challenges

Advanced Imaging Solutions

  • Count and measure solution 
  • Three-dimensional image display and measurement

Solutions for Metallography

  • Grain sizing using the intercept counting method
  • Grain sizing using the planimetric method 
  • Graphite nodularity evaluation
  • Rating the non-metallic inclusion content
  • Comparison of sample images with reference standards
  • Dendrite arm spacing measurement

Solutions for Machinery Processing (Automotive / Machined Parts Industries)

  • Welding distortion
  • Phase and region of interest measurement
  • Particle distribution 

Solutions for Electronics (Electronic Device / Semiconductor Industries)

  • Throwing power measurement
  • Automatic critical dimension measurement

Solutions for Surface Coatings and Thin Film Deposits (Coating Industries)

  • Thin coating thickness evaluation (calotest method)
  • Layer thickness measurement
  • Pore fraction and density measurement

Specifications

■: Standard □: Optional Start Basic Essentials Motion Desktop
Image Acquisition Basic image acquisition including HDR and auto-calibration of magnification and Live HDR*1, and position navigation*1

 

Software autofocus*2 and movie acquisition (Avi format)

 

 

Time lapse, Instant EFI, and Instant/Manual MIA*3

 

 

Motorized EFI/MIA and Z-stack acquisition

 

 

Remote live view (NetCam)

 

 

Image and Customization Tools Basic tool windows (Image history, properties, navigator, gallery view tool window)*4
Annotations, layer management, scale bar, cross hair, info stamp display, and image filters
Digital reticle/grid, line profile display, My Function, layout management, and Macro Manager

 

Measurements/ Image Analysis Basic interactive measurement (distance, angles, rectangles, circles, ellipses, polygons, circle-to-circle distance, angle ruler, and line ruler) and data export to MS-Excel
Phase analysis, magic wand, freehand polyline, interpolated polygon, morphology filter, and image arithmetics

 

3D measurements, 3D profile measurements, and 3D surface view

 

Reporting*5 Report creation (MS-Word, and MS-Excel formats) 

 

Presentation creation

 

Data Management Stream document storage*6

 

Workgroup Database with structured data format

 

Device Support Olympus microscopes*7 and Olympus cameras*8

 

Non-Olympus cameras and image source converter*9

 

 

Non-Olympus stage controller*9

 

 

 

PC Requirements

CPU Intel Core 2 Duo or higher (Intel Core i5, i7 recommended)
RAM / Hard disk / DVD drive 3 GB or more (8 GB recommended)/2.4 GB or more free space/DVD+R DL compatible
OS*10 Windows 10 Pro (32-bit/64-bit) , Windows 8.1 (32-bit/64-bit) Pro, Windows 7 (32-bit/64-bit) Ultimate with SP1, Windows 7 (32-bit/64-bit) Professional with SP1
.NET Framework Version 4.5.2 or 4.6.1
Graphic card*11 1280 × 1024 monitor resolution with 32-bit video card
Web browser Windows Internet Explorer 8, 9, 10, or 11

*1   Requires the DP74 camera, and the Live HDR function requires 64-bit OS. 
*2   Requires Olympus microscope with motorized Z-axis or external motorized Z-axis with OLYMPUS Stream Motion or Automation Solution 
*3   Instant MIA may not work properly with some cameras 
*4   Write and read all major file formats and open Olympus proprietary formats (DSX, LEXT and POIR file formats) 
*5   Requires Microsoft Office 2016, 2013 (SP1) or 2010 (SP2) 
*6   Using Microsoft SQL Server Express 
*7   Supports MX61A, MX61, MX61L, MX61A, MX63L, MX63, GX53, BX3M-CB, BX3M-CBFM, BX-UCB, BX-REMCB, IX-UCB, SZX-MDCU, SZX2-MDCU, U-CBS, STM7. 
*8   Supports DP21, DP22, DP26, DP27, DP73, DP74, LC20, LC30, SC30, SC50, SC100, SC180, UC30, UC50, UC90, XC10, XC30, XC50, XM10. 
*9   Please contact Olympus for supported device information 
*10 The DP74 supports Windows 10/8.1 (64-bit) and Windows 7 (32-bit/64-bit). The DP73 supports Windows 8.1/7 (64-bit). The SC180/UC90 support Windows 10/8.1/7 (64-bit). 
*11 Required configurations for LiveHDR in DP74. Graphic board applicable to CUDA made by NVIDIA (compute capability 2.1 or higher). Graphic board driver applicable to CUDA 7.0 or higher.